Titre original (traduit automatiquement) : Siemens Software Center Vulnerability Exploited in ClickFix Malware Attacks
Résumé de la source, en anglais
présente une vulnérabilité critique (CVE-2026-110936) permettant à un attaquant authentifié local d'exécuter du code arbitraire en exploitant un chemin de recherche non contrôlé pour les bibliothèques DLL. Siemens recommande une mise à jour immédiate vers la version 4.0.9.8 ou ultérieure, avec auto-mise à jour au prochain redémarrage. Des mesures de sécurisation réseau et d'isolement des systèmes de contrôle sont préconisées par CISA pour minimiser les risques d'exploitation.
The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application. Siemens has released a new version for Siemens Software Center and recommends to update to the latest version. Please refer to our blog post for additional information about current known active exploitation and how to detect it.
The following versions of Siemens Software Center are affected:
| CVSS | Vendor | Equipment |
|---|---|---|
| v3 6.7 | Siemens | Siemens Software Center |
| 1 Vulnerability |
|---|
| Uncontrolled Search Path Element |
Product Status: known_affected
Vendor fix
Update to V4.0.9.8 or later version (All existing versions of SSC will be auto updated on next startup. The latest version can also be downloaded in the respective link)
Relevant CWE: CWE-427 Uncontrolled Search Path Element
| CVSS Version | Base Score | Base Severity | Vector String |
|---|---|---|---|
| 3.1 | 6.7 | MEDIUM | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H |
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
This ICSA is a verbatim republication of Siemens ProductCERT SSA-580366 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.
| Date | Revision | Summary |
|---|---|---|
| 2026-10-15 | 1 | Publication Date |
| 2026-10-17 | 2 | Added remediation for Siemens Software Center |
| 2026-10-19 | 3 | Added reference to blog post about active exploitation of the vulnerability |
| 2026-10-22 | 4 | Initial CISA Republication of Siemens ProductCERT SSA-580366 advisory |
Source originale
cisa.gov
Attackers exploit Siemens Software Center flaw in active ClickFix malware campaign ↗
helpnetsecurity.com · 20 oct.
ClickFix Attackers Exploit Siemens Software Center Flaw to Deploy Remote Access Trojan ↗
thehackernews.com · 20 oct.
Siemens Software Center Vulnerability Exploited in ClickFix Malware Attacks ↗
securityweek.com · 19 oct.